- Size
- 1200 x 600 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 160 L NEA (237 L rated)
- Energy
- 5 ticks · 321 kWh/yr
Undercounter chillers for Singapore kitchens
Chillers, freezers and dual-zone counters that sit under your prep line, from 890 mm to 2,100 mm wide and 450, 600, 750 or 760 mm deep. 74 of the 83 are on the official EEG equipment list, and every tick, kWh and NEA volume on this page comes from the NEA registry. Cold is easy. Holding it steady through a busy service is what keeps ingredients fresh.
Rated volume is the maker's figure. NEA net volume is what NEA measured as usable storage. Compare NEA with NEA.
83 undercounter chillers
- Size
- 1200 x 600 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 162 L NEA (238 L rated)
- Energy
- 5 ticks · 343 kWh/yr
Fukushima Galilei AYC-121PXA-SI
- Size
- 1200 x 600 x 800 mm
- Temp
- Chiller -5 to 10°C, freezer -25 to -15°C
- Volume
- 141 L NEA (211 L rated)
- Energy
- 4 ticks · 1,175 kWh/yr
- Size
- 1200 x 600 x 800 mm
- Temp
- -25 to -15°C
- Volume
- 160 L NEA (237 L rated)
- Energy
- 4 ticks · 1,259 kWh/yr
- Size
- 1200 x 600 x 800 mm
- Temp
- -25 to -15°C
- Volume
- 162 L NEA (238 L rated)
- Energy
- 3 ticks · 1,434 kWh/yr
- Size
- 1200 x 750 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 216 L NEA (312 L rated)
- Energy
- 5 ticks · 423 kWh/yr
Alan Law has repaired commercial fridges in Singapore since 1985. We deliver, install and service what we sell.
See our published repair rates- Size
- 1200 x 750 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 217 L NEA (313 L rated)
- Energy
- 5 ticks · 453 kWh/yr
Fukushima Galilei AYW-121PXA-SI
- Size
- 1200 x 750 x 800 mm
- Temp
- Chiller -5 to 10°C, freezer -25 to -15°C
- Volume
- 190 L NEA (279 L rated)
- Energy
- 4 ticks · 1,212 kWh/yr
- Size
- 1200 x 750 x 800 mm
- Temp
- -25 to -15°C
- Volume
- 216 L NEA (312 L rated)
- Energy
- 4 ticks · 1,241 kWh/yr
- Size
- 1200 x 750 x 800 mm
- Temp
- -25 to -15°C
- Volume
- 217 L NEA (313 L rated)
- Energy
- 4 ticks · 1,434 kWh/yr
- Size
- 1500 x 600 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 222 L NEA (325 L rated)
- Energy
- 5 ticks · 380 kWh/yr
- Size
- 1500 x 600 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 223 L NEA (326 L rated)
- Energy
- 5 ticks · 380 kWh/yr
Fukushima Galilei AYC-151PXA-SI
- Size
- 1500 x 600 x 800 mm
- Temp
- Chiller -5 to 10°C, freezer -25 to -15°C
- Volume
- 203 L NEA (297 L rated)
- Energy
- 4 ticks · 1,288 kWh/yr
- Size
- 1500 x 600 x 800 mm
- Temp
- -25 to -15°C
- Volume
- 222 L NEA (325 L rated)
- Energy
- 4 ticks · 1,449 kWh/yr
- Size
- 1500 x 600 x 600 mm
- Temp
- -25 to -15°C
- Volume
- 223 L NEA (326 L rated)
- Energy
- 3 ticks · 1,683 kWh/yr
- Size
- 1500 x 750 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 299 L NEA (426 L rated)
- Energy
- 4 ticks · 515 kWh/yr
- Size
- 1500 x 750 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 300 L NEA (428 L rated)
- Energy
- 4 ticks · 533 kWh/yr
Fukushima Galilei AYW-151PXA-SI
- Size
- 1500 x 750 x 800 mm
- Temp
- Chiller -5 to 10°C, freezer -25 to -15°C
- Volume
- 273 L NEA (392 L rated)
- Energy
- 4 ticks · 1,376 kWh/yr
- Size
- 1500 x 750 x 800 mm
- Temp
- -25 to -15°C
- Volume
- 299 L NEA (426 L rated)
- Energy
- 4 ticks · 1,489 kWh/yr
- Size
- 1500 x 750 x 800 mm
- Temp
- -25 to -15°C
- Volume
- 300 L NEA (428 L rated)
- Energy
- 3 ticks · 1,653 kWh/yr
- Size
- 1800 x 600 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 282 L NEA (411 L rated)
- Energy
- 5 ticks · 453 kWh/yr
- Size
- 1800 x 600 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 279 L NEA (413 L rated)
- Energy
- 5 ticks · 438 kWh/yr
- Size
- 1800 x 750 x 800 mm
- Temp
- -5 to 10°C
- Volume
- 379 L NEA (540 L rated)
- Energy
- 4 ticks · 610 kWh/yr
- Size
- 1800 x 750 x 800 mm
- Temp
- Chiller -5 to 10°C, freezer -25 to -15°C
- Volume
- 352 L NEA (505 L rated)
- Energy
- 4 ticks · 1,515 kWh/yr
- Size
- 1800 x 750 x 800 mm
- Temp
- -25 to -15°C
- Volume
- 379 L NEA (538 L rated)
- Energy
- 4 ticks · 1,774 kWh/yr
- Size
- 900 x 450 x 800 mm
- Temp
- 2 to 10°C
- Volume
- 139 L, maker figure
- Energy
- Not on NEA registry
- Size
- 900 x 600 x 800 mm
- Temp
- 2 to 10°C
- Volume
- 197 L, maker figure
- Energy
- Not on NEA registry
- Size
- 1200 x 450 x 800 mm
- Temp
- 2 to 10°C
- Volume
- 207 L, maker figure
- Energy
- Not on NEA registry
- Size
- 1200 x 600 x 800 mm
- Temp
- 2 to 10°C
- Volume
- 293 L, maker figure
- Energy
- Not on NEA registry
- Size
- 1500 x 450 x 800 mm
- Temp
- 2 to 10°C
- Volume
- 274 L, maker figure
- Energy
- Not on NEA registry
- Size
- 1500 x 600 x 800 mm
- Temp
- 2 to 10°C
- Volume
- 388 L, maker figure
- Energy
- Not on NEA registry
- Size
- 1200 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 255 L NEA
- Energy
- 5 ticks · 292 kWh/yr
- Size
- 1200 x 760 x 840 mm
- Temp
- -18 to -12°C
- Volume
- 255 L NEA
- Energy
- 4 ticks · 1,022 kWh/yr
- Size
- 1500 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 356 L NEA
- Energy
- 5 ticks · 402 kWh/yr
- Size
- 1500 x 760 x 840 mm
- Temp
- -18 to -12°C
- Volume
- 356 L NEA
- Energy
- 4 ticks · 1,351 kWh/yr
- Size
- 1800 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 459 L NEA
- Energy
- 5 ticks · 475 kWh/yr
- Size
- 1800 x 760 x 840 mm
- Temp
- -18 to -12°C
- Volume
- 458 L NEA
- Energy
- 4 ticks · 1,606 kWh/yr
- Size
- 2100 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 559 L NEA
- Energy
- 5 ticks · 475 kWh/yr
- Size
- 2100 x 760 x 840 mm
- Temp
- -18 to -12°C
- Volume
- 559 L NEA
- Energy
- 4 ticks · 1,570 kWh/yr
- Size
- 1200 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 258 L, maker figure
- Energy
- Not on NEA registry
- Size
- 1200 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 258 L, maker figure
- Energy
- Not on NEA registry
- Size
- 1500 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 361 L, maker figure
- Energy
- Not on NEA registry
- Size
- 1500 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 361 L, maker figure
- Energy
- Not on NEA registry
- Size
- 1800 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 464 L, maker figure
- Energy
- Not on NEA registry
- Size
- 1800 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 464 L, maker figure
- Energy
- Not on NEA registry
- Size
- 2100 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 566 L, maker figure
- Energy
- Not on NEA registry
- Size
- 2100 x 760 x 840 mm
- Temp
- +2 to +8°C
- Volume
- 566 L, maker figure
- Energy
- Not on NEA registry
- Size
- 900 x 600 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 97 L NEA
- Energy
- 5 ticks · 380 kWh/yr
- Size
- 900 x 600 x 850 mm (+H150 leg)
- Temp
- -25 to -7°C
- Volume
- 97 L NEA
- Energy
- 4 ticks · 1,004 kWh/yr
- Size
- 900 x 600 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 97 L NEA
- Energy
- 4 ticks · 475 kWh/yr
- Size
- 900 x 750 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 131 L NEA
- Energy
- 5 ticks · 358 kWh/yr
- Size
- 900 x 750 x 850 mm (+H150 leg)
- Temp
- -25 to -7°C
- Volume
- 131 L NEA
- Energy
- 4 ticks · 1,102 kWh/yr
- Size
- 900 x 750 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 131 L NEA
- Energy
- 4 ticks · 489 kWh/yr
- Size
- 1200 x 600 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 156 L NEA
- Energy
- 4 ticks · 719 kWh/yr
- Size
- 1200 x 600 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 156 L NEA
- Energy
- 4 ticks · 807 kWh/yr
- Size
- 1200 x 600 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 156 L NEA
- Energy
- 4 ticks · 613 kWh/yr
- Size
- 1200 x 750 x 850 mm (+H150 leg)
- Temp
- -25 to -7°C
- Volume
- 212 L NEA
- Energy
- 4 ticks · 1,340 kWh/yr
- Size
- 1200 x 750 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 212 L NEA
- Energy
- 4 ticks · 756 kWh/yr
- Size
- 1200 x 750 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 212 L NEA
- Energy
- 4 ticks · 883 kWh/yr
- Size
- 1200 x 750 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 212 L NEA
- Energy
- 4 ticks · 562 kWh/yr
- Size
- 1400 x 750 x 570 mm
- Temp
- -6 to +12°C
- Volume
- 53 L NEA
- Energy
- 4 ticks · 734 kWh/yr
- Size
- 1500 x 600 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 215 L NEA
- Energy
- 4 ticks · 785 kWh/yr
- Size
- 1500 x 600 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 215 L NEA
- Energy
- 4 ticks · 861 kWh/yr
- Size
- 1500 x 600 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 215 L NEA
- Energy
- 4 ticks · 631 kWh/yr
- Size
- 1500 x 750 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 292 L NEA
- Energy
- 4 ticks · 657 kWh/yr
- Size
- 1500 x 750 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 292 L NEA
- Energy
- 4 ticks · 872 kWh/yr
- Size
- 1500 x 750 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 292 L NEA
- Energy
- 4 ticks · 588 kWh/yr
- Size
- 1800 x 600 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 274 L NEA
- Energy
- 4 ticks · 803 kWh/yr
- Size
- 1800 x 750 x 850 mm (+H150 leg)
- Temp
- -6 to +12°C
- Volume
- 371 L NEA
- Energy
- 4 ticks · 807 kWh/yr
- Size
- 890 x 600 x 850 mm
- Temp
- -25 to -15°C
- Volume
- 118 L NEA
- Energy
- 4 ticks · 858 kWh/yr
- Size
- 890 x 750 x 850 mm
- Temp
- -25 to -15°C
- Volume
- 160 L NEA
- Energy
- 4 ticks · 894 kWh/yr
- Size
- 1200 x 600 x 850 mm
- Temp
- -6 to +12°C
- Volume
- 181 L NEA
- Energy
- 5 ticks · 318 kWh/yr
- Size
- 1200 x 600 x 850 mm
- Temp
- -25 to -15°C
- Volume
- 181 L NEA
- Energy
- 4 ticks · 1,040 kWh/yr
- Size
- 1200 x 750 x 850 mm
- Temp
- -6 to +12°C
- Volume
- 248 L NEA
- Energy
- 5 ticks · 431 kWh/yr
- Size
- 1200 x 750 x 850 mm
- Temp
- -25 to -15°C
- Volume
- 248 L NEA
- Energy
- 4 ticks · 1,033 kWh/yr
- Size
- 1500 x 600 x 850 mm
- Temp
- -6 to +12°C
- Volume
- 250 L NEA
- Energy
- 5 ticks · 387 kWh/yr
- Size
- 1500 x 600 x 850 mm
- Temp
- -25 to -15°C
- Volume
- 250 L NEA
- Energy
- 4 ticks · 1,164 kWh/yr
- Size
- 1500 x 750 x 850 mm
- Temp
- -6 to +12°C
- Volume
- 341 L NEA
- Energy
- 5 ticks · 427 kWh/yr
- Size
- 1500 x 750 x 850 mm
- Temp
- -25 to -15°C
- Volume
- 341 L NEA
- Energy
- 4 ticks · 1,296 kWh/yr
- Size
- 1800 x 600 x 850 mm
- Temp
- -6 to +12°C
- Volume
- 316 L NEA
- Energy
- 5 ticks · 460 kWh/yr
- Size
- 1800 x 600 x 850 mm
- Temp
- -25 to -15°C
- Volume
- 316 L NEA
- Energy
- 4 ticks · 1,657 kWh/yr
- Size
- 1800 x 750 x 850 mm
- Temp
- -6 to +12°C
- Volume
- 432 L NEA
- Energy
- 5 ticks · 515 kWh/yr
- Size
- 1800 x 750 x 850 mm
- Temp
- -25 to -15°C
- Volume
- 432 L NEA
- Energy
- 4 ticks · 1,646 kWh/yr
No models match these filters.
Compare models
How to choose an undercounter chiller
An undercounter chiller is two things at once: your prep bench, and the cold store your line reaches into all service. Get these seven things right and the rest is detail.
Match the depth to your bench line
Most models here are 600 mm or 750 to 760 mm deep, with a few slim 450 mm units. Match your bench line so the worktop runs flush. Depth also buys space: at the same 1.5 m width, Fukushima Galilei's 600 mm AYC-150RXA-SI holds 222 L and the 750 mm AYW-150RXA-SI holds 299 L (both NEA measured).
Pick the width, and the doors follow
| Width | Models | Usual doors | NEA net volume |
|---|---|---|---|
| 90 cm | 10 | 1 door (or 2 sliding glass) | 97 to 160 L |
| 120 cm | 27 | 2 doors | 141 to 255 L |
| 150 cm | 27 | 2 doors | 203 to 356 L (plus a 53 L drawer unit at 1,400 mm) |
| 180 cm | 15 | 2 or 3 doors | 274 to 459 L |
| 210 cm | 4 | 3 doors | 559 L |
Measure the space, then the way in: door frames, lift, corners.
Chiller, freezer or both
Chillers here run -5 to 10°C (Fukushima Galilei counters; its sliding glass-door counters run 2 to 10°C), -6 to +12°C (Hoshizaki, Panasonic) or +2 to +8°C (Berjaya). Freezers run -25 to -15°C (Fukushima Galilei, Panasonic), -25 to -7°C (Hoshizaki) or -18 to -12°C (Berjaya). Chiller-freezer counters give you both in one body. Use the Type filter.
Centre pillar or pillarless
In Fukushima Galilei model codes, F means centre pillarless. On the AYW-150RXA-SI the two doors close against a fixed centre pillar; the AYW-150RXFA-SI leaves the full width open. Choose pillarless if you load wide trays or GN pans, or want the whole inside open for cleaning. Choose the centre pillar if you do a lot of preparation work on top, such as heavy chopping or making dough.
Read the ticks, then the kWh
NEA labels commercial storage fridges from 1 to 5 ticks. Two counters with the same ticks can still differ a lot in kWh per year, so compare the number, not only the ticks. For the EEG, regulated commercial storage fridges need at least 4 NEA ticks; other commercial fridges, such as back-bar display chillers, qualify with inverter technology. What NEA ticks mean for your power bill
Ask how fast it recovers
Every door opening lets warm air in. What protects your stock is how quickly the counter pulls back to temperature in the middle of service, not the lowest number on its display. Ask us how a model holds up in a busy service. Every door opening starts a clock
Plan the delivery
Send photos of your counter space and the access route (stairs, lift, tight corners) with your enquiry. Delivery and any stair or over-counter handling are planned with the quote.
Not sure? Send your bench measurements on WhatsApp and we will tell you what fits.
Buying from the people who service them
Alan Law started repairing commercial fridges in Singapore in 1985. We still do the repairs.
Every tick, kWh and NEA volume here comes from the NEA registry, with the registration number on each model page.
We deliver, install and service what we sell. Our repair rates are published.
See the repair ratesThe 74 models on the official EEG equipment list carry a green mark. Your company makes the application; our guide explains the steps.
How the grant worksUndercounter chiller questions
Is an undercounter chiller the same as a counter chiller?
Yes. Singapore kitchens say undercounter chiller, counter chiller or under-counter fridge for the same thing: refrigerated storage under a stainless worktop. Fukushima Galilei calls it a table type refrigerator.
Should I choose 600 mm or 750 mm deep?
Match your bench line first, so the worktop runs flush. If you have the room, 750 mm holds noticeably more: 299 L against 222 L for Fukushima Galilei's 1.5 m pair (NEA measured).
Which models are on the EEG equipment list?
74 of the 83 models here are on the official GoBusiness EEG supported-equipment list; tick "On the EEG equipment list" in the filters. Your company applies directly, and the application must be submitted before you pay anything or place an order, including a deposit. Our guide walks through the steps.
How long does delivery take?
Fukushima Galilei counters built in Thailand are usually pre-order, about 4 to 6 weeks; the Japan-made LRC-180RX, about 8 to 12 weeks. Berjaya: about 3 to 6 weeks. Hoshizaki: ex stock, subject to availability; otherwise 4 to 12 weeks. Panasonic: ex stock, subject to availability. We confirm stock and lead time with your quote, usually the same day.
Who services it after I buy?
We do. The team that delivers and installs your counter is the team that services it, and our repair rates are published.
Tell us your bench size. We will tell you what fits.
A real person replies, usually the same day.
We use your details only to reply to this enquiry, under our privacy policy (PDPA).